美國FDA質(zhì)量管理體系QSR820咨詢返回首頁

QSR 820 法規(guī)從1996年發(fā)布以來,歷史上進行了6次小型的技術(shù)修改。如下

 

Technical Amendment
Federal Register Citation

65 FR 17136
(31-Mar-2000)

Change removed paragraphs (e) and (f) from 820.1 Scope.

PART 820—QUALITY SYSTEM REGULATION
7. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 351, 352, 360, 360c, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.
8. Amend § 820.1 by removing paragraphs (e) and (f).


65 FR 66636
(07-Nov-2000)

Change restored paragraph (e) to 820.1 Scope.

 

PART 820—QUALITY SYSTEM REGULATION
5. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.
6. Section 820.1 is amended by adding paragraph (e) to read as follows:
§ 820.1 Scope.
* * * * *
(e) Exemptions or variances. (1) Any person who wishes to petition for an exemption or variance from any device quality system requirement is subject to the requirements of section 520(f)(2) of the act. Petitions for an exemption or variance shall be submitted according to the procedures set forth in § 10.30 of this chapter, the FDA’s administrative procedures. Guidance is available from the Center for Devices and Radiological Health, Division of Small Manufacturers Assistance (HFZ–220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1–800–638–2041 or 1–301–443–6597, FAX 301–443–8818.

(2) FDA may initiate and grant a variance from any device quality system requirement when the agency determines that such variance is in the best interest of the public health. Such variance will remain in effect only so long as there remains a public health need for the device and the device would not likely be made sufficiently available without the variance.


69 FR 11313
(10-Mar-2004)

Change removed reference to 21 CFR 804, which was deleted from the CFR.

 

PART 820—QUALITY SYSTEM REGULATION
14. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l 371, 374, 381, 383.
15. Section 820.198(d) is revised to read as follows
§ 820.198 Complaint files.
* * * * *
(d) Any complaint that represents an event which must be reported to FDA under part 803 of this chapter shall be promptly reviewed, evaluated, and investigated by a designated individual(s) and shall be maintained in a separate portion of the complaint files or otherwise clearly identified. In addition to the information required by § 820.198(e), records of investigation under this paragraph shall include a determination of:
(1) Whether the device failed to meet specifications;
(2) Whether the device was being used for treatment or diagnosis; and
(3) The relationship, if any, of the device to the reported incident or adverse event.
* * * * *
16. Section 820.200(c) is revised to read as follows:
§ 820.200 Servicing.
* * * * *

c) Each manufacturer who receives a service report that represents an event which must be reported to FDA under part 803 of this chapter shall automatically consider the report a complaint and shall process it in accordance with the requirements of § 820.198.


69 FR 29829
(25-May-2004)

Changed to specifically note applicability of 21

CFR 820 to tissue products, under newly released 21 CFR 1271.

Also, the Quality System regulation contains a typographic error: it has a date of 2005, but 2004 is the correct date.

 

PART 820—QUALITY SYSTEM REGULATION
6. The authority citation for 21 CFR part 820 is revised to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383; 42 U.S.C. 216, 262, 263a, 264.
7. Section 820.1 is amended by adding two sentences to the end of paragraph (a)(1), and by revising paragraph (b) to read as follows:
§ 820.1 Scope.
(a) Applicability. (1) * * *
Manufacturers of human cells, tissues, and cellular and tissue-based products (HCT/Ps), as defined in § 1271.3(d) of this chapter, that are medical devices (subject to premarket review or notification, or exempt from notification, under an application submitted under the device provisions of the act or under a biological product license application under section 351 of the Public Health Service Act) are subject to this part and are also subject to the donor-eligibility procedures set forth in part 1271 subpart C of this chapter and applicable current good tissue practice procedures in part 1271 subpart D of this chapter. In the event of a conflict between applicable regulations in part 1271 and in other parts of this chapter, the regulation specifically applicable to the device in question shall supersede the more general.
* * * * *
(b) The quality system regulation in this part supplements regulations in other parts of this chapter except where explicitly stated otherwise. In the event of a conflict between applicable regulations in this part and in other parts of this chapter, the regulations specifically applicable to the device in question shall supersede any other generally applicable requirements.


71 FR 16228
(31-Mar-2006)

Change removed reference to 21 CFR 804, which was deleted from the CFR.

PART 820—QUALITY SYSTEM REGULATION
3. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.

4. Amend paragraph (a)(3) of § 820.198 by removing ‘‘or 804’’.


72 FR 17397
(09-Apr-2007)

Change updated title, address, and phone numbers for DSMICA.

PART 820—QUALITY SYSTEM REGULATION

6. FDA is revising Sec.  820.1(e) and replacing “Division of Small Manufacturers Assistance (HFZ-220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1-800-638-2041 or 1-301-443-6597, FAX 301-443-8818” with “Division of Small Manufacturers, International and Consumer Assistance (HFZ-220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1-800-638-2041 or 240-276-3150, FAX 240-276-3151.”

企業(yè)介紹 | 法律聲明 | 網(wǎng)站地圖 | 認證查詢 | 資料下載 | 在線留言 | 聯(lián)系方式
上海沃華產(chǎn)品技術(shù)服務(wù)有限公司 Copyright 2025 www.qianqianmu.cn, 版權(quán)所有 滬ICP備16037738號-1
電話:021-51088618;400-016-1080 地址:上海市長寧區(qū)天山路641號慧谷白貓科技園1號樓701室
友情鏈接: CE認證 | BIM咨詢 | 深圳注冊公司

滬公網(wǎng)安備 31010502002363號


国产α片免费观看在线人 | 精品国产乱码久久久久久下载 | 国产日韩欧美一区二区会员 | 999www人成免费视频 | 偷窥 亚洲 色 国产 日韩 | 国产99久久久久久免费看农村 | 国产在线自在拍91精品 | 欧美日韩精品久久久免费观看 | 日韩精品极品视频在线观看免费 | 亚洲高清无码视频在线观看 | 人妻插B视频一区二区三区 欧美精品中文字幕亚洲专区 | 欧美日韩中文国产一区发布 | 亚洲日韩高清在线亚洲专区 | 国产精品夜夜爽张柏芝 | 日韩欧美~中文字幕无敌色 亚洲成Aⅴ人片乱码色午夜 | 亚洲乱码国产一区三区 | 国产精品原巨作AV无遮挡 | 精品爆乳动漫一区二区在线 | 国产精一品亚洲二区在线播放 | 国产精品看高国产精品不卡 | 综合久久国产九一剧情麻豆 | 精品人妻少妇一区二区三区在线。 | 精品深夜AV无码一区二区老年 | 一区二区三区波多野结衣在线观看 | 久久超碰高清熟女一区二区 | 2020久久国内精品视频 | 少妇人妻精品一区二区三区 | 日韩丰满少妇无吗视频激情内射 | 中字幕视频在线永久在线观看免费 | 欧美熟妇另类久久久久久不卡 | 久久国产无码模特视频 | 免费精品久久久久久中文字幕 | 欧美男男纯肉巨黄作爱视频 | 侧所偷拍一区二区三区四区 | 亚州欧美中文字幕精品综合 | 四虎亚洲中文字幕无码永久 | 插我一区二区在线观看 | 久久精品免费一区二区喷潮 | 1024国产精品视频一区 | 中文字幕久久久久人妻中出 | 无码色AV一二区在线播放 |